Third-party test reports

15 reports from SGS-CSTC (Shenzhen) and Centre Testing International (Hangzhou), listed with the report number, the sample name the laboratory printed, the method and the limits stated on the report itself. A report covers the sample tested — nothing more — so the scope of each one is spelled out rather than implied.

RoHS 2.0 & halogen

RoHS 2.0 & halogen

Restricted substances under EU RoHS, plus fluorine, chlorine, bromine and iodine.

Report no.LaboratorySample as named on the report IssuedResult & method
SZXEC26002546001_1
Signed by Tina Fan
Supersedes SZXEC26002546001 of 2026-04-30
SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Acetate cloth tape
Construction-level
2026-05-07
tested 2026-04-27 – 2026-04-30
RoHS: Pass. Halogen: fluorine, chlorine, bromine and iodine all not detected.
Method: IEC 62321 series; halogen by EN 14582:2016 (IC)
SZXEC26002546003_1
Signed by Tina Fan
Supersedes SZXEC26002546003 of 2026-04-30
SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Flame-retardant cotton cloth tape
Construction-level
2026-05-07
tested 2026-04-27 – 2026-04-30
RoHS: Pass. Halogen: fluorine, chlorine, bromine and iodine all not detected.
The Chinese original names the sample 阻燃醋酸布胶带 — flame-retardant acetate cloth tape. The English page of the same report says "cotton". That is an error in the laboratory's own translation, reproduced here unaltered; the sample submitted was the flame-retardant acetate-cloth grade.
Method: IEC 62321 series; halogen by EN 14582:2016 (IC)
SZXEC26002546009_1
Signed by Tina Fan
Supersedes SZXEC26002546009 of 2026-04-30
SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Nylon Fabric Tape
Construction-level
2026-05-07
tested 2026-04-27 – 2026-04-30
RoHS: Pass. Halogen: fluorine, chlorine, bromine and iodine all not detected.
Method: IEC 62321 series; halogen by EN 14582:2016 (IC)
SZXEC26002546005_1
Signed by Tina Fan
Supersedes SZXEC26002546005 of 2026-04-30
SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Conductive Fabric Tape
Construction-level
2026-05-07
tested 2026-04-27 – 2026-04-30
RoHS: Pass. Halogen: fluorine, chlorine, bromine and iodine all not detected.
Method: IEC 62321 series; halogen by EN 14582:2016 (IC)
SZXEC26002546007_1
Signed by Tina Fan
Supersedes SZXEC26002546007 of 2026-04-30
SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Polyester fabric
Construction-level
2026-05-07
tested 2026-04-27 – 2026-04-30
RoHS: Pass. Halogen: fluorine, chlorine, bromine and iodine all not detected.
The polyester greige. Our own test schedule records the submitted sample as fabric code 290-CX in black; the report itself prints only the sample name, so it is listed here as construction-level.
Method: IEC 62321 series; halogen by EN 14582:2016 (IC)
SZXEC26002546011_1
Signed by Tina Fan
Supersedes SZXEC26002546011 of 2026-04-30
SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Tearable cloth
Construction-level
2026-05-07
tested 2026-04-27 – 2026-04-30
RoHS: Pass. Halogen: fluorine, chlorine, bromine and iodine all not detected.
The acetate greige — a different fibre from the polyester greige above, not a colour variant of it. Our own test schedule records the submitted sample as fabric code P073 in black; the report itself prints only the sample name.
Method: IEC 62321 series; halogen by EN 14582:2016 (IC)
A2250904513101001 Centre Testing International Corporation (Hangzhou) Model No. K8030
Model-level — K8030
2025-12-06
tested 2025-12-03 – 2025-12-06
RoHS: Pass. Halogen: chlorine 91 mg/kg; fluorine, bromine and iodine not detected (reporting limit 10 mg/kg).
Method: IEC 62321 series; halogen by EN 14582:2016 (IC)
A2250904513101002 Centre Testing International Corporation (Hangzhou) Model No. K8026/75100 (black)
Model-level — K8026-00, K75100-00
2025-12-06
tested 2025-12-03 – 2025-12-06
RoHS: Pass. Halogen: fluorine, chlorine, bromine and iodine all not detected (reporting limit 10 mg/kg).
Method: IEC 62321 series; halogen by EN 14582:2016 (IC)
REACH SVHC

REACH SVHC

Screening against the REACH candidate list and the substances intended for identification.

Report no.LaboratorySample as named on the report IssuedResult & method
A2250940638101001 Centre Testing International Corporation (Hangzhou) Acetate Cloth Tape
Construction-level
2025-12-23
tested 2025-12-16 – 2025-12-23
All tested SVHC not detected; SVHC concentrations ≤ 0.1 % (w/w).
Method: Candidate-list screening plus substances intended for identification
A2250904513102001 Centre Testing International Corporation (Hangzhou) Velvet wire harness tape (K8030)
Model-level — K8030
2025-12-23
tested 2025-12-03 – 2025-12-23
All tested SVHC not detected; SVHC concentrations ≤ 0.1 % (w/w).
Method: Candidate-list screening plus substances intended for identification
A2250904513102002 Centre Testing International Corporation (Hangzhou) Easy to tear / wear-resistant tape for wiring harness (K8026/K75100, black)
Model-level — K8026-00, K75100-00
2025-12-06
tested 2025-12-03 – 2025-12-06
All tested SVHC not detected; SVHC concentrations ≤ 0.1 % (w/w).
Method: Candidate-list screening plus substances intended for identification
A2250904513102003 Centre Testing International Corporation (Hangzhou) Easy to tear / wear-resistant tape for wiring harness (K8026/K75100, orange)
Model-level — K8026-00, K75100-00
2025-12-25
tested 2025-12-03 – 2025-12-23
All tested SVHC not detected; SVHC concentrations ≤ 0.1 % (w/w).
Method: Candidate-list screening plus substances intended for identification
A2250975736101001E Centre Testing International Corporation (Hangzhou) Conductive cloth tape (EP212-2110SS)
Model-level — EP212-2110SS
2026-01-04
tested —
All tested SVHC not detected; SVHC concentrations ≤ 0.1 % (w/w).
Method: Candidate-list screening plus substances intended for identification
A2250904513102004 Centre Testing International Corporation (Hangzhou) V0 flame retardant tape
Construction-level
2025-12-23
tested 2025-12-03 – 2025-12-23
All tested SVHC not detected; SVHC concentrations ≤ 0.1 % (w/w).
Method: Candidate-list screening plus substances intended for identification
Flammability

Flammability

Burning behaviour measured to a published method.

Report no.LaboratorySample as named on the report IssuedResult & method
A2260546319101
Signed by Wesley Mao (approved signatory No. R49CCD354C)
Centre Testing International Corporation (Hangzhou) Flame retardant acetic acid cloth tape
Construction-level
2026-07-07
tested 2026-07-01 – 2026-07-07
All five specimens: afterflame t1 = 0 s, t2 = 0 s, afterglow t3 = 0 s; no flaming particles or drops; cotton indicator not ignited; no burning to the holding clamp. Meets the V-0 requirements.
Two limits stated on the report itself. First, only the room-temperature preconditioning set was run (23 ± 2 °C, 50 ± 10 % RH, ≥ 48 h); a full UL 94 V-0 classification also requires the aged condition set. Second, the laboratory prints that the data is "just for scientific research, education, internal quality control and product development". It is a third-party test to the UL 94 method — not a UL classification, not a UL file, and not a substitute for one.
Method: UL 94-2023 and client requirements; horizontal/vertical burning tester FRTS-UL94-A; flame height 20 ± 1 mm, two 10 ± 0.5 s applications; specimens 125 × 13 × 0.2 mm
Reading these

What these reports do and do not prove

A test report is not a certification

A laboratory report states what was measured on a submitted sample on a given date. It is not a certificate, a listing or a mark, and it does not transfer to a different construction. Our certifications — IATF 16949, UL Recognized Component file E544340, OEKO-TEX and GRS — are listed separately on Quality & standards, with their issuers, numbers and dates.

Construction-level versus model-level

The sample is named on the report by product category, so the result covers that construction, not one model number. Four reports name a model and are marked model-level. Where your drawing requires the report to carry your model number, say so at enquiry and we submit that model — we do not re-label an adjacent grade’s report.

One code on these reports is a fabric, not a tape

The flame-retardant reports also cover V073-193 — the flame-retardant acetate base fabric, supplied uncoated. It is a fabric, not a finished tape, which is why it does not appear among the tape datasheets. Uncoated fabric is sold to converters who apply their own adhesive; see the base-fabric datasheets, and ask for V073-193 by name if you need the flame-retardant grade.

Measured values, not labels

Halogen results are given as measured concentrations with the reporting limit, not as a “halogen-free” claim, because the threshold depends on the specification you work to. The same applies to flammability: we publish the burn figures and the method, and let the specification decide.

Frequently asked questions

Are these reports for the exact model I am buying?

Read the Scope line. Where the laboratory printed a model number — K8030, K8026/75100, EP212-2110SS — the report is model-level. The rest name a product category, so they cover that construction and we present them that way. If your drawing needs a report in your model's name, we submit that model for test and send you the report with the number on it.

Do you hold a UL 94 V-0 classification?

No. We hold a third-party vertical-burn test to the UL 94 method (CTI report A2260546319101, 7 July 2026) in which all five specimens met the V-0 requirements with zero afterflame and no flaming drips. Two limits are printed on that report: only the room-temperature preconditioning set was run, and the laboratory states the data is for research and internal quality control. Separately we hold UL Recognized Component file E544340 under ANSI/CAN/UL 510A for tape type Z1V020 — that is a different standard and is not a UL 94 classification.

Is the tape halogen-free?

The reports give measured values rather than a label. On the six SGS reports of 7 May 2026 fluorine, chlorine, bromine and iodine were all not detected. On the CTI report for K8030 chlorine was 91 mg/kg with fluorine, bromine and iodine not detected; for K8026/75100 in black all four were not detected. Compare those figures against the threshold your specification uses — we do not apply the label on your behalf.

The two greige-fabric reports — are they the same cloth in two colours?

No, they are two different fibres. SZXEC26002546007_1 covers the polyester greige and SZXEC26002546011_1 covers the acetate greige. We weave and sell both, and a tape's properties follow the fibre its base cloth is woven from, so ask which one a given tape is built on rather than assuming.

Why does one report say "cotton"?

SGS report SZXEC26002546003_1 names the sample 阻燃醋酸布胶带 — flame-retardant acetate cloth tape — in Chinese and "Flame-retardant cotton cloth tape" in English. That is an error in the laboratory's own translation. We reproduce the report as issued rather than editing it, and have asked for a corrected English page.

How long is a report valid?

A test report has no expiry; it describes the sample tested on the date shown. We re-test on a yearly cycle and the renewal date in our own schedule is listed with each report, so you can see how current the data is.

Can I have the PDFs?

Yes — ask for the models you are quoting and we send the signed PDFs, in Chinese and English where both exist. Reports are reproduced only in full, as the laboratories require.